domestic cooling systems
The modern and traditional cooling systems such as air conditioning, ventilation, or radiant cooling, and their energy saving principles.
Heating, ventilation, air conditioning and refrigeration engineering technicians aid in the design of devices which provide heating, ventilation, air conditioning and possibly refrigeration in buildings. They ensure the equipment complies with environmental standards. They handle hazardous materials used in the systems, and ensure safety precautions are in place.
No competences in this bucket.
The modern and traditional cooling systems such as air conditioning, ventilation, or radiant cooling, and their energy saving principles.
Electric heating systems contribute to indoor comfort and energy saving under the right conditions (low frequency use, or very highly insulated buildings). They include InfraRed and electric floor/wall heating.
Discipline that applies principles of physics, engineering and materials science to design, analyse, manufacture and maintain mechanical systems.
Various types of heat pumps, used to produce heating, cooling and potable hot water making use of an energy source with low temperature and bringing it to a higher temperature.
The different parts constituing heating, air conditioning and refrigeration systems such as the different valves, fans, compressors, condensers, filters and other components.
The power transmission systems that use the force of flowing liquids to transmit power.
The characteristics and properties of the different fluids used in heat pump and refrigeration cycles.
The branch of physics that deals with the relationships between heat and other forms of energy.
No competences in this bucket.
Interpret and understand plans and drawings in manufacturing processes which include representations in two dimensions.
Monitor equipment which provides utility services such as power, heat, refrigeration, and steam, in order to ensure they are functional, operate according to regulations, and to check for faults.
Operate climate control installations.
Adhere to standards of hygiene and safety established by respective authorities.
Check machinery and equipment to ensure reliable performance during use and operations in worksites.
Monitor activities and perform tasks ensuring compliance with standards involving environmental protection and sustainability, and amend activities in the case of changes in environmental legislation. Ensure that the processes are compliant with environment regulations and best practices.
Handle the different transfer pumps used to keep a refrigerant in the liquid phase at the right pressure for an optimal accuracy and speed of the charging station.
Interpret and understand plans and drawings in manufacturing processes which include representations in three dimensions.
Keep written records of all repairs and maintenance interventions undertaken, including information on the parts and materials used, etc.
Use equipment to test performance and operation of machinery.
No competences in this bucket.
Energy production for heating and potable hot water making use of biogas (the biogas is generated off-site), and its contribution to energy performance.
District heating and cooling exploits local sustainable sources of energy to provide heating and potable hot water to a group of buildings and contributes to improve the energy performance.
No competences in this bucket.
Attach fire resistant collars or material to pipes and ducts to prevent the spread of fire and smoke through wall or ceiling openings.
Install refrigeration, air condition or heat pump equipment, connect components and piping, attach equipment to the electrical network and secondary sources of heat transfer if required.
Perform refrigerant leak checks of refrigeration, air condition or heat pump equipment to make sure there are no leaks of refrigerant from the system using both direct and indirect method.
Perform system pressure tests on refrigeration, air condition or heat pump equipment using pressurised gas and vacuum pump to check tightness of the refrigeration circuit and its parts.
Investigate and advise on a ventilation system that fits the energy demands but also guarantees good indoor air quality according to minimum indoor air quality levels. Consider alternative ways of ventilation (e.g., stack ventilation, use of chimney effect, natural ventilation).
Arrange for equipment repairs when necessary.
Drain substances which pose health and safety risks from equipment, appliances or installations in order to store the liquids according to safety guidelines and dispose or treat them as required.
Provide power connection from copper or metal busbars.
Analyse the principles that need to be considered for engineering designs and projects such as functionality, replicability, costs and other principles.
Install air conditioning devices, which remove heat, and often moisture, from the air through a variety of mechanisms. Create the necessary openings through walls and floors and place the device. Connect it to a power supply. Configure the device.
Install equipment which is dependent on electric currents or electromagnetic fields in order to work, or equipment to generate, transfer or measure such currents and fields. This equipment includes switchboards, electric motors, generators or direct current systems.
Place heating, ventilation, air conditioning and refrigeration boilers, which heats up water and circulates it through a closed radiator system to distribute heat around a structure. Connect the boiler to a source of fuel or electricity and to the circulation system. Connect it to the water supply if it features an automatic filling system. Configure the boiler.
Place a furnace which heats air to be distributed around a structure. Connect the furnace to a source of fuel or electricity and connect any air ducts to guide the heated air. Configure the furnace.
Install ducts to deliver and remove air. Determine whether the duct should be flexible or not, and select the appropriate material based on projected usage. Waterproof and airproof the duct and insulate it against temperature influence to ensure maximum efficiency and prevent contamination with mould. Make the correct connections between the ducts and endpoints.
Install equipment to enable the ventilation of a structure. Mount fans and install air inlets and outlets. Install ducts to permit the transfer of air. Configure the ventilation system if it is electronically controlled.
Install the system of pipes used to transport a fluid, be it a liquid or a gas, from one point to another and connect it to the fuel and water supply lines, air ducts, and other components.
Lead, supervise and motivate a group of people, in order to meet the expected results within a given timeline and with the foreseen resources in mind.
Perform the maintenance on installed equipment on-site. Follow procedures to avoid uninstalling equipment from machinery or vehicles.
Identify, report and repair equipment damage and malfunctions. Communicate with field representatives and manufacturers to obtain repair and replacement components.
Make use of protection equipment according to training, instruction and manuals. Inspect the equipment and use it consistently.